Maintenance jic female swivel fitting:
1, the swivel british fittings should be kept inside the drum and pipe cleaning. The new equipment should pay particular attention to the need to add a filter, if necessary, in order to avoid abnormal wear caused by foreign matter on the rotary joint.
2, due to long-term use can cause the machine rotary joint internal scaling and rust from Please note there will be card dead or leakage occurs when situations such as re-use.
3, with oiling device periodically oiling, to ensure the reliability of the rotary joint bearing operation.
4, the rotary joint body medium heat circulating students should gradually warm to avoid abrupt changes in temperature.
5. Check the sealing surface of the wear condition and thickness changes; observe the sealing surface friction track, to see whether there is intermittent or three, scratches and other issues, if the situation on the case, should be replaced immediately.
6. The rotary joint should be gently prohibited by the impact, in order to avoid the loss of the joint member.